Siemens SIMOVERT MASTERDRIVES Manual page 1151

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Parameter
Description
P195*
Function parameter for entering the smoothing time
Smooth Pos Act
constant for the actual position.
195
P196*
BICO parameter for selecting the connector from which
S.SetV PosAct
the setting value for smoothing of the actual position is to
be read in.
196
P197*
BICO parameter for selecting the binector from which the
S.Set PosAct
command for setting smoothing of the actual position is to
be read in.
197
r198
Visualization parameter for displaying the deviation
PosActSetp Diff
(actual/setpoint difference) of the position controller.
198
P199*
Function parameter fo entering the smoothing time
Smooth Pos Diff
constant for the devation (actual/setpoint difference) of
the position controller.
199
r200
Visualization parameter for displaying the position setpoint
Pos Setp PosReg
directly at the input of the position controller.
200
r201
Visualization parameter for displaying the actual position
Pos ActV PosReg
directly at the input of the position controller.
201
P202*
BICO parameter for selecting the connector from which
S.PosRegLim
the output limitation of the position controller is to be read
in.
202
P203*
BICO parameter for selecting the connector from which
S.PosRegAdapt
the input signal for gain adaptation of the position
controller is to be read in.
203
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0,0
Menus:
Min: 0,0
- Parameter menu
Max: 1000,0
+ Control/gating unit
Unit: ms
+ Position control
Indices: 4
- Upread/free access
,FDS
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Position control
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Position control
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Control/gating unit
Type: I4
+ Position control
- Upread/free access
index1: 0,0
Menus:
Min: 0,0
- Parameter menu
Max: 1000,0
+ Control/gating unit
Unit: ms
+ Position control
Indices: 4
- Upread/free access
,FDS
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Control/gating unit
Type: I4
+ Position control
- Upread/free access
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Control/gating unit
Type: I4
+ Position control
- Upread/free access
index1: 134
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Position control
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
index1: 1
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Position control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
34