Parameter
Description
U369
Parameter for entering a fixed setpoint value for the
TeCntrFStpOutLim
output limitation ramp-function generator of the
technology controller.
2369
U370*
BICO parameter for selecting the connectors for the
S.TeCntrOutLim
output limitation of the technology controller.
Index 1: Connector for upper output limitation (B+)
2370
Index 2: Connector for lower output limitation (B-)
U371
Parameter for entering the acceleration/deceleration time
TeCntrOutLimTime
for the output limitation of the technology controller.
2371
n372
Visualization parameter, output of the technology
TeCntr Output
controller after output limitation.
2372
U373*
BICO parameter for selecting the connector from which
S.J_Ext
the moment of inertia for torque pre-control is read in.
2373
U374*
BICO parameter for selecting a connector from which the
S.AccPre
acceleration for torque pre-control is read in.
2374
U375*
BICO parameter for selecting a connector from which a
S.T FixVal
fixed torque pre-control value is read in.
2375
U376*
BICO parameter for selecting a binector from which the
S.Select J
command to select a fixed (U378) or a variable moment of
inertia (U373) for torque pre-control is read in
2376
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
Init: 100,0
Menus:
Min: 0,0
- Parameter menu
Max: 200,0
+ Free blocks
Unit: %
- Upread/free access
Indices: -
Changeable in:
Type: I2
- Ready to switch on
index1: 586
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 100,00
+ Free blocks
Unit: s
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
Dec.Plc.: 1
Menus:
Unit: %
- Parameter menu
Indices: -
+ Free blocks
Type: I2
- Upread/free access
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
161