Parameter
Description
P683*
Parameter for selecting the connector whose value has to
EB2 S.AnaOut
be output at the analog output on EB2.
683
Index 1: First inserted EB2
Index 2: Second inserted EB2
P684*
Parameter for configuring the analog output on EB2. The
EB2 AnaOutConf
sign with which the value of the connector selected in
P683 has to be output at the analog output is selected
684
here.
0 = Do not change sign
1 = Always output value with positive sign
2 = Invert sign
3 = Always output value with negative sign
Index 1: First inserted EB2
Index 2: Second inserted EB2
P685*
Parameter for entering the smoothing time constant for
EB2AnaOutSmooth
the analog output on EB2.
685
Index 1: First inserted EB2
Index 2: Second inserted EB2
P686*
Parameter for scaling the analog output on EB2. With the
EB2 AnaOutNorm
help of the entered parameter value, it is determined
which analog output voltage an internal signal value of
686
100% (4000 H) should correspond to.
Index 1: First inserted EB2
Index 2: Second inserted EB2
P687
Parameter for entering the offset for the analog output on
EB2 AnaOutOffset
EB2. The offset is added to the already scaled analog
output signal.
687
Index 1: First inserted EB2
Index 2: Second inserted EB2
r688
Visualization parameter for displaying the actual value
EB2 AnaOut Value
which is connected to the analog output of EB2.
688
Index 1: First inserted EB2
Index 2: Second inserted EB2
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Terminals
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 3
+ Terminals
Unit: -
- Upread/free access
Indices: 2
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 10000
+ Terminals
Unit: -
- Upread/free access
Indices: 2
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
index1: 10,00
Menus:
Min: -200,00
- Parameter menu
Max: 200,00
+ Terminals
Unit: V
- Upread/free access
Indices: 2
Changeable in:
Type: I2
- Ready to switch on
- Operation enabled
index1: 0,00
Menus:
Min: -200,00
- Parameter menu
Max: 200,00
+ Terminals
Unit: V
- Upread/free access
Indices: 2
Changeable in:
Type: I2
- Ready to switch on
- Operation enabled
Dec.Plc.: 2
Menus:
Unit: %
- Parameter menu
Indices: 2
+ Terminals
Type: I2
- Upread/free access
83