Siemens SIMOVERT MASTERDRIVES Manual page 513

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Communication / CBC
r731.02
r731.03
r731.04
r731.05
r731.10
r731.11
8.4-58
Value
(hex)
39
Overlapping of CAN identifier PKW-broadcast <->
PZD-receive-Multicast
3A
Overlapping of CAN identifier PKW-broadcast <->
PZD-receive cross
3B
Overlapping of CAN identifier PZD-receive <-> PZD-send
3C
Overlapping of CAN identifier PZD-receive <->
PZD-receive-Broadcast
3D
Overlapping of CAN identifier PZD-receive <->
PZD-receive multicast
3E
Overlapping of CAN identifier PZD-receive <->
PZD-receive cross
3F
Overlapping of CAN identifier PZD-send <->
PZD-receive broadcast
40
Overlapping of CAN identifier PZD-send <->
PZD-receive multicast
41
Overlapping of CAN identifier PZD-send <-> PZD-receive cross
42
Overlapping of CAN identifier PZD-receive broadcast <->
PZD-receive multicast
43
Overlapping of CAN identifier PZD-receive broadcast <->
PZD-receive cross
Overlapping of CAN identifier PZD-receive multicast <->
44
PZD-receive cross
Counter PZD-receive CAN telegrams
Counter for PZD CAN telegrams received error-free since voltage ON.
Counter Lost PZD CAN telegrams
Counter for lost PZD telegrams since voltage ON. If the CAN-bus
master sends process-data telegrams faster than the slave can process
them, telegrams are lost. These lost telegrams are totaled here.
Counter Bus-Off
Counter of the bus-off states since voltage ON (alarm A084).
Counter Error-Warning
Counter of the error-warning states since voltage ON (alarm A083).
Counter PZD-send CAN telegrams
Counter for PZD telegrams sent error-free since voltage ON.
Counter Errors PZD-send CAN telegrams
Counter for errors during sending of PZD telegrams, i.e. when a PZD
telegram was to be sent but it was not possible, e.g. in the case of bus
overload.