Siemens SIMOVERT MASTERDRIVES Manual page 837

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

05.2006
Engaging/
disengaging
New parameters
Extended
parameters
New connectors
New binectors
(synchronism status
signals FD846)
Siemens AG
6SE7087-6QX70 (Version AG)
SIMOVERT MASTERDRIVES
The total length of the acceleration/deceleration ramp U610 must not
be more than the engaging/disengaging length U611. The
engaging/disengaging length U611 must be at least as long as the total
length of the acceleration/deceleration ramp U610.
From MASTERDRIVES version 1.6 as an alternative to the
engaging/disengaging length, a disengaging position (special
configuration U475=1) can also be specified, at which the constant
travel phase of the engaging action is completed (see also function
diagram 834a, column 1, note <3>).
From MASTERDRIVES version 2.1, in addition to the disengaging
position the acceleration and the deceleration ramp can also be
specified differently (special configuration U475 = 11, see also function
diagram 834b, column 1, note <4>).
If the disengaging position (DISENG) lies before the total of
acceleration starting point (ENG) and deceleration ramp end (ACC-RA),
the point ((ACC-RA') or (DEC-RA')) is determined as a result thereof
(from MASTERDRIVES version 2.2 with special configuration
U475=111, see also function diagram 834c, column 1, note <4>).
♦ U474
"Src Variable Ramps" has been newly introduced
• U474.1 Length of acceleration ramp [LU] WE:894
• U474.2 Length of deceleration ramp [LU] WE:894
♦ U609
has been extended to two indices
• U609.1 Source offset of engaging position [LU] WE:822
• U609.2 Source disengaging position [LU] WE:821
♦ U610
has been extended to two indices
• U610.1 Total length of acceleration/decleration ramp [LU] WE:1
• U610.2 Total length of acceleration/deceleration ramp [LU]
WE:0
♦ U613
has been extended to two indices
• U613.1 Offset of engaging position [LU] WE:0
• U613.2 Disengaging position [LU] WE:0
♦ KK0821
Disengaging position
♦ KK0894
Total length of acceleration ramp
♦ KK0895
Total length of ramp
♦ B0801
In acceleration ramp (BIT20)
♦ B0802
In deceleration ramp (BIT21)
♦ B0814
Change to Src. Variable Ramps permitted (bit 22)
Compendium Motion Control
Technology Option F01
9-189

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents