02.2004
8.5.8.2
Evaluation of CBC diagnostic parameter
Siemens AG
6SE7087-6QX70 (Version AD)
SIMOVERT MASTERDRIVES
The CBC stores diagnostic data in a diagnostic buffer to support
commissioning and servicing activities. The diagnostic information can
be read out with indexed parameter r732.i (CB/TB diagnosis). This
parameter is displayed in hexadecimal notation.
The CBC diagnostics buffer is assigned as follows:
Meaning
r 732.01
Error identifier configuration (1)
r 732.02
Not used
r 732.03
Not used
r 732.04
Not used
r 732.05
Not used
r 732.06
Not used
r 732.07
Not used
r 732.08
Not used
r 732.09
Not used
r 732.10
Not used
r 732.11
Not used
r 732.12
Not used
r 732.13
Not used
r 732.14
Counter for properly processed PKW tasks (incl. response)
r 732.15
Counter for errors in processing PKW tasks (incl. response)
r 732.16
Error type of error in processing PKW tasks
r 732.17
Error value of error in processing PKW tasks
r 732.18
Not used
r 732.19
Parameter which cannot be read out during initialization. (only MC)
r 732.20
Not used
r 732.21
Not used
r 732.22
Not used
r 732.23
Not used
r 732.24
Not used
r 732.25
Not used
r 732.26
Software version
r 732.27
Software identifier
r 732.28
Software date 'Day/Month'
r 732.29
Software date 'Year'
Compendium Motion Control
Communication / CBC CANopen Communication Board