Siemens SIMOVERT MASTERDRIVES Manual page 1366

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Parameter
Description
U937*
Control signals of shift register
Src SR CntrlSig
Index 1: Write clock shift register 1
2937
L-H edge is switching edge
Index 2: Read clock shift register 1
L-H edge is switching edge
Index 3: Reset shift register 1
high active
Index 4: Reset multiplexer shift register 1
high active
Index 5: Shift direction shift register 1
0 = forwards
1= backwards
Index 6: Correction trigger shift register 1
L-H edge trips correction action
Index 7: Enable data shift register 1
0 = Output of P2936.3 at data output
1= Output of current dataset at data output
Index 1 - 7: [FD787a]
Index 8: Write clock shift register 2
L-H edge is switching edge
Index 9: Read clock shift register 2
L-H edge is switching edge
Index 10: Reset shift register 2
high active
Index 11: Reset multiplexer shift register 2
high active
Index 12: Shift direction shift register 2
0 = fowards
1= backwards
Index 13: Correction trigger shift register 2
L-H edge trips correction action
Index 14: Enable data shift register 2
0 = Output of P2936.6 at data output
1= Output of current dataset at data output
Index 8 - 14: [FD787b]
n938
Visualization parameter status shift register
SR Status
Index 1: Shift register 1 [FD787a]
2938
Index 2: Shift register 2 [FD787b]
n939
Visualization parameter connector output shift register
SR OutputKK
Index 1: Shift register 1 [FD787a]
2939
Index 2: Shift register 2 [FD787b]
n940
Visualization parameter for connectors in dataset shift
SR1 RegisterKK
register
n940: Shift register 1 [FD787a]
2940
n942: Shift register 2 [FD787b]
Index 1: Dataset 01
Index 2: Dataset 02
...
Index 50: Dataset 50
n941
Visualization parameter for binectors in dataset shift
SR1 RegisterBi
register
n941: Shift register 1 [FD787a]
2941
n943: Shift register 2 [FD787b]
Index 1: Dataset 01
Index 2: Dataset 02
...
Index 50: Dataset 50
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 14
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
- Upread/free access
Type: V2
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
- Upread/free access
Type: I4
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: 50
+ Free blocks
Type: I4
- Upread/free access
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: 50
+ Free blocks
Type: V2
- Upread/free access
249