Parameter
Description
U402*
Parameter for selecting the double word connector for the
S.ConnAnaDE_2
2nd analog delay element
2402
U403*
Parameter for entering the delay cycles of the 2nd analog
AnaDE_2_T
delay element
2403
U404*
Parameter array for selecting the binectors for the 6
S.SampTChange
sampling time changeover contacts
2404
U405*
Parameter for selecting the 32-bit connector for the high-
S.MulDiv32_1_32
resolution multiplier/divider 1 (2-word)
2405
U406*
Parameter for selecting the 16-bit connectors for the high-
S.MulDiv32_1_16
resolution multiplier/divider 1 (2-word)
2406
U407*
Parameter for selecting a connector as input for
S.PulsGen Tp
determination of the period of the 1st pulse generator
2407
U408*
Parameter array for selecting the double-word connectors
S.Integr32_1
for the 1st 32-bit integrator:
Index 1: Current input value
2408
Index 2: Upper limit
Index 3: Lower limit
Index 4: Set value
U409*
Parameter for selecting the integral time constant for the
S.Integr32_1_t
1st 32-bit integrator.
2409
U410*
Parameter for selecting a binector as setting command for
S.Integr32_1_s
the 1st 32-bit integrator.
2410
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 32
+ Free blocks
Unit: -
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 6
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 613
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 4
+ Free blocks
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
Init: 611
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
165