Parameter
Description
U536*
Parameter for selecting the binector from which the fast
S.QuickInp
digital input signals E1 ... E6 for positioning are to be
read. 6 fast signals can be defined. The function of these
2536
fast signals is determined via MD45 (U501.45) and MD46
(U501.46).
Function diagram [813.1]
U537*
The parameter defines the source for the technological
S.TechInputs.P
inputs for positioning. Checkback signals from the basic
functions are softwired to these inputs. The following
2537
softwiring is expected
Index 01: Only used for test purposes.
Index 02: Checkback - "Homing position detected"
(Motor encoder: B210)
Index 03: Only used for test purposes.
Function diagram [815.4]
U538*
The parameter defines the source for the checkback of
S.MVal Valid
position sensing that a valid position measured value is
available.
2538
The binector is set by position sensing if, e.g., a printing
index is detected. The following sources are available:
1. Position sensing with motor encoder: B212
2. Position sensing with external machine encoder: B217
Function diagram [815.4]
U539*
Parameter defines the source for the position measured
S.Mvalue
value. The measured value is provided by the position
sensing, e.g.
2539
- KK122 from motor encoder in slot c
- KK127 from external machine encoder
Function diagram [815.4]
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
(external machine encoder: B215)
Data
Read/write
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 6
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 3
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
Init: 212
Menus:
Unit: -
- Parameter menu
Indices: -
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
- Upread/free access
Type: L2 ,K
Changeable in:
,K
- Ready to switch on
- Operation enabled
188