Siemens SIMOVERT MASTERDRIVES Manual page 1020

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

U317
B
Priority:
1. Enable counter
2. Set counter
B
3. Stop counter
4. Count up/down
B
B
B
U316
Counter minimum value
0 ... 65535
K0561
K
U315.1 (0)
Counter maximum value
0 ... 65535
K0562
K
U315.2 (65535)
Counter setting value
0 ... 65535
K0563
K
U315.3 (0)
Counter starting value
0 ... 65535
K0564
K
U315.4 (0)
<1>
After POWER ON the counter is set to the starting value.
<2>
Starting value and setting value are limited to the range (minimum value... maximum value).
<3>
Example: The counter is operating in the 3.2 ms time slot -> max. counting frequency 156 Hz.
Attention: The sampling time and sampling sequence of the upstream signal processing has to be taking into account!
1
2
Free blocks
Software counter
Software counter 16 bit (maximum counting frequency: 1/ [2 x sampling time]) {4 µs}
.01 (0)
Count up
.02 (0)
Count down
.03 (0)
Stop counter
.04 (0)
Set counter
.05 (1)
Enable counter
.01 (561)
Minimum value
.02 (562)
Maximum value
.03 (563)
Setting value <2>
.04 (564)
Starting value <2>
POWER ON
[X4.4]
3
<3>
&
UP
&
DOWN
1
(Binary code)
1
Set counter to
minimum
value
Set counter to
setting value
Set counter to
starting value
<1>
4
5
V2.4
Counter output
0...65535
n318
OUT
K0565
Overflow
B0490
Underflow
B0491
Example: Minimum value = 2, Maximum value = 7
7
6
Counter output
5
5
4
4
3
3
2
Count up
Count down
2
Overflow
Underflow
6
7
Function diagram
fp_mc_785_e.vsd
MASTERDRIVES MC
23.10.02
U951.38 = ___(20)
7
7
7
6
6
6
5
5
4
4
4
3
3
3
2
2
2
2
7
7
8
- 785 -