Connector number
KK0843
KK0844
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES
Connector name
Description
Status Table 6
Bit 0 to 15: Number of support values
(up to last fault-free support value)
Bit 16 to 23: Fault code
Bit 24: Table reset running
Bit 25: Table transfer running
Bit 26 to Bit 29: Spare
Bit 30: Group fault
Bit 31: Transfer finished and fault-free
Fault code
0: No fault
1: Number of support values = 0 or
higher maximum number of support
points
2: Position value of master axis higher
than table width
3: Position value of master axis not
rising
4: Data block not present (M7)
5: Data block too short (M7)
Last correct support point number in
the event that an error has occurred
during transfer to the table. The next
support point is therefore the faulty
support point.
See fault code.
In function diagramm: 839d.2, 839e.2
Status Table 7
Bit 0 to 15: Number of support values
(up to last fault-free support value)
Bit 16 to 23: Fault code
Bit 24: Table reset running
Bit 25: Table transfer running
Bit 26 to Bit 29: Spare
Bit 30: Group fault
Bit 31: Transfer finished and fault-free
Fault code
0: No fault
1: Number of support values = 0 or
higher maximum number of support
points
2: Position value of master axis higher
than table width
3: Position value of master axis not
rising
4: Data block not present (M7)
5: Data block too short (M7)
Last correct support point number in
the event that an error has occurred
during transfer to the table. The next
support point is therefore the faulty
support point.
See fault code.
In function diagramm: 839d.2, 839e.2
Compendium Motion Control
DSP
Double word
no
yes
no
yes