Siemens SIMOVERT MASTERDRIVES Manual page 620

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

02.2004
r732.16
r732.17
Siemens AG
6SE7087-6QX70 (Version AD)
SIMOVERT MASTERDRIVES
Error type with PKW task "processing error".
An error identifier is entered in this parameter if an error occurs in the
processing of PKW tasks.
Value (hex)
Meaning
0x0
No error
0x4
DPR error: errored status byte
0x5
DPR error: errored control byte, programming error in
task/response channel or an attempt has been made using
object 4001 to start a parameter task which has not been
implemented
0xA
Programming error in parameter status
0xB
The basic unit has not processed the transmitted parameter
task within the timeout of 150 ms (or 300 ms).
PKW-
With response identifier 7: Task cannot be executed
PKE/IND
or
with response identifier 8: No PKW control command source
status
Error value with PKW task "processing error".
Contains additional information about a particular error type.
With error types 0x4 and 0x5:
Value (hex)
Meaning
0x0
No error
0x1
Error in task channel
0x2
Error in response channel
0x66
Channel not wide enough
0x6A
Task not implemented
With error types 0xA and 0xB:
Value (hex)
Meaning
PKW-
Task identifier and parameter index of transmitted
PKE/IND
parameter task
Error value for a PKW response with response identifier 7 or 8:
See Subsection 8.5.3.1, Parameter Download.