Parameter
Description
U486*
Function parameter for entering the trigger condition
TriggerCondition
If a bit trigger (U485) is set, only parameter value 1 is
2486
permissible. If parameter values 3, 5 and 6 are set,
parameters U483, U484 are not significant. In the case of
parameter values 5 and 6, parameter U489 is used for the
trigger condition.
Parameter value
0 = Trigger if trigger input < trigger threshold
1 = Trigger if trigger input = trigger threshold
2 = Trigger if trigger input > trigger threshold
3 = Trigger if fault
4 = Trigger if trigger input <> trigger threshold
5 = Trigger if binector trigger input = 1
6 = Trigger if binector trigger input = 0
Indices: Index = channel number
U487*
Function parameter for entering the size of the pretrigger.
PreTrigger
Parameter value:
2487
Relation of the number of data recorded before the trigger
event to the total number as a percentage. Example: 40 %
means that 40% of the data in the trace buffer were
recorded before the trigger event and 60% after the trigger
event.
Indices: Index = channel number
U488*
Function/visualization parameter of the trace status.
TraceStatusStart
The trace consists of a maximum of 8 channels
corresponding to Indices 1 to 8.The trace memory is
2488
dynamically distributed according to the number of
channels activated.
Only parameter values 0 and 1 can be set.
If the parameter value is set from 0 to 1, all recorded data
of all channels are lost (because the whole trace memory
is erased) and the trace is activated for this channel. If the
trigger condition is satisfied and another channel is in the
process of recording (parameter value 2), no further
channel can be activated (parameter value 1).
Parameter values:
0 = Trace not active/recording finished
1 = Trace active/trace is waiting for trigger event
2 = Trace is recording
Indices: Index = channel number
U489*
BICO parameter for selection of trace as trigger to
S.BTriggerInput
binectors used.
2489
Indices: Index = channel number
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 6
+ Diagnostics
Unit: -
+ Trace
Indices: 8
- Upread/free access
Type: O2
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 100
+ Diagnostics
Unit: %
+ Trace
Indices: 8
- Upread/free access
Type: O2
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 2
+ Diagnostics
Unit: -
+ Trace
Indices: 8
- Upread/free access
Type: O2
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 8
+ Diagnostics
Type: L2 ,B
+ Trace
- Upread/free access
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
177