Tracking/Storage Elements; Analog Signal Storages - Siemens SIMOVERT MASTERDRIVES Manual

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

1 Maximum selection (2-word) {4 µs}
U952.24 = __ (20)
U201 (0)
.01
x1
KK
.02
x2
KK
MAX
.03
x3
KK
y = Maximum of x1, x2, x3
(e.g. -40 % greater than -50 %)
1 Minimum selection (2-word) {4 µs}
U952.25 = __ (20)
U202 (0)
.01
x1
KK
.02
x2
KK
MIN
.03
x3
KK
y = Minimum of x1, x2, x3
(e.g. -50 % less than -40 %)
1
2
Free blocks
Minimum/maximum selection, tracking/storage elements
U950.76 = __ (20)
U203 (0)
B
B
B
y
KK0545
U204 (0)
KK
<1>
U205 = 0:
No 'non-volatile'
storage
U205 = 1:
'Non-volatile'
storage
U210 (0)
B
U209 (0)
y
KK
KK0546
POWER ON
3
2 tracking / storage elements (2-word) {3 µs}
y=x
1
freeze y
.01
Power On Mode
.02
U205 (0)
.03
<1>
TRACK
x
y
KK0551
STORE
Priority:
1. RESET
RESET (y=0)
2. TRACK
3. STORE
2 analog signal storages (2-word) {2 µs}
U950.77 = __ (20)
SET
(y=x)
x
y
KK0553
RESET
(y=0)
4
5
V2.4
U952.69 = __ (20)
y=x
1
U206 (0)
freeze y
.01
B
.02
B
.03
B
TRACK
U207 (0)
KK
x
<1>
U208 = 0:
No 'non-volatile'
storage
U208 = 1:
RESET (y=0)
'Non-volatile'
storage
U952.50 = __ (20)
U212 (0)
SET
B
(y=x)
U211 (0)
KK
x
RESET
POWER ON
(y=0)
6
7
Function diagram
fp_mc_760_e.vsd
MASTERDRIVES MC
23.10.02
Power On Mode
U208 (0)
<1>
y
KK0552
STORE
Priority:
1. RESET
2. TRACK
3. STORE
y
KK0554
8
- 760 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents