Siemens SIMOVERT MASTERDRIVES Manual page 970

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Applies only to induction motors
(P95=2 or P95=4)
Rotor time const.
0 ... 10000 ms
P124 (0 ms)
Max. deviation
0.0
Max. deviation
-0.6 * P124
Isq(act) > 0.15 * P102
n(act) > 3Hz
y
1
0
x
y
1
0
x
1
2
Tr-Adaptation for asynchronous machines
Bit2 status_word1
Operation / Pulses blocked
+
+
y
For P92=0.00% the
adaptation is switched off
x
(less computing time)
Integrator is reset with
Bit2 status_word1 =
pulse blocked
n(act)
Isq(act)
3
4
Tr Actual value
[%]
r093
0
1
Tr-Adaptation Kp
0.00 ... 200.00 %
P092 (0.00 %)
Tr-Adaptation
Isd(act)
usq(act),
P111.1 to .10
P121
usd(act)
Ls=f(isd)
Stator
resistance
5
6
V2.4
fp_mc_394_e.vsd
08.01.02
Actual value of rotor
time constant Tr
for flux model [390.6]
P122
P123
Total contr
Stator
reactance
reactance
7
8
Function diagram