Siemens SIMOVERT MASTERDRIVES Manual page 1036

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Data format setpoint:
31
Setpoint (0...32767)
Setpoint:
Position setpoint of the master axis
Setting value: Position of the zero pulse referred to the master axis
Bit:
0 = SLE deactivated; 0->1 Load SLE with setting value; 1 = SLE active
Data format actual value:
31
Actual value (0...32767)
Actual value:
SLE actual value
Bit:
0 = Not initialized; 1 = SLE active
1
2
Free blocks
Setpoint Supply SIMOLINK Encoder SLE
Function Block, Setpoint Supply SIMOLINK Encoder SLE
Dead time adaption
-100.00 ... 100.00 ms
U807 (0.00)
Rated speed
0.00 ... 20 000 000.00 [1000 LU/min]
U806 (0.00)
Src.SLE act.speed
U803.04 (0)
KK
Axis cycle length
1... 231-1 [LU]
U805 (32768)
Src.Setpoint
from virtual master to SIMOLINK
U803.01 (0)
KK
Src.SLE offset
U803.02 (0)
KK
activate SLE
U804 (0)
B
Src.SLE actual value telegram
from SIMOLINK transmission channel
U803.03 (0)
KK
17
16
15
x
Setting value (0...32767)
17
16
15
x
x
3
ACL
<1>
1
0
Bit
1
0
Bit
4
5
V2.4
KK0850
Setpoint deadtime adapted from master
Setpoint supply SLE
KK0848
to SIMOLINK transmission channel
SLE actual value
K0849
SLE active
B0835
<1>
Offset gives the position of the zero pulse
relative to the setpoint (U803.01).
With rising edge at U804.
The function block is used for simple setpoint correction of the
SIMOLINK Encoder SLE (Order No. 6SX7005-0AG0). The
Handbook "SLE/SLE-DP SIMOLINK Encoder" describes the
SIMOLINK Encoder and the function block and also contains
notes on configuring.
6
7
Function diagram
fp_mc_793_e.vsd
MASTERDRIVES MC
02.02.04
U953.28 = __ (20)
8