Siemens SIMOVERT MASTERDRIVES Manual page 1279

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Parameter
Description
U377*
BICO parameter for selecting a binector from which the
S.Sel Acc T
command to select a fixed (U375) is read in or from the
pre-control torque calculated from acceleration.
2377
U378*
Parameter for indicating a fixed moment of inertia for the
J FixVal
torque pre-control.
2378
Normialization
n_ref (P353)
------------------------------
m_ref (P354)
Thus the rated starting time is given in seconds.
U379*
Parameter for indicating the scaling of the external
J / Scaling
moments of inertia (U373)
2379
U380*
BICO parameter for selecting the connector for the input
S.SimpRGen In
of the simple ramp-function generator.
2380
U381*
BICO parameter for selecting the binector for setting the
S.Set SimpRGen
simple ramp-function generator.
2381
U382*
BICO parameter for selecting the connector for the setting
S.SetVSimpRGen
value of the simple ramp-function generator.
2382
U383
Parameter for entering the acceleration and deceleration
SimpRG Ac/DcTime
time of the simple ramp-function generator.
Index 1: Acceleration time
2383
Index 2: Deceleration time
n384
Parameter is only necessary for the parameter model of
KPC PROFIdriveV
PROFIdrive V3 standard. Parameter is only visible if
PROFIdrive V3 is set.
2384
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 600,00
+ Control/gating unit
Unit: s
+ Speed control
Indices: -
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
- Operation enabled
Init: 100,00
Menus:
Min: 0,00
- Parameter menu
Max: 200,00
+ Control/gating unit
Unit: %
+ Speed control
Indices: -
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 10,00
Menus:
Min: 0,00
- Parameter menu
Max: 100,00
+ Free blocks
Unit: s
- Upread/free access
Indices: 2
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
Dec.Plc.: 3
Menus:
Unit: 1/s
- Parameter menu
Indices: -
- Upread/free access
Type: O4
- Ready to switch on
162

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents