Siemens SIMOVERT MASTERDRIVES Manual page 573

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Communication / CBC CANopen Communication Board
Error code
Meaning
(hex)
FF00
external fault 1
FF01
external fault 2
FF02
PIN is missing
FF03
Fault 1 Function blocks
FF04
Fault 2 Function blocks
FF05
Fault 3 Function blocks
FF06
Fault 4 Function blocks
FF07
SIMOLINK start Alarm
FF08
Drive not synchronous
FF09
Simulation active alarm
FF10
External alarm 1
FF11
External alarm 2
FF12
Alarm 1 Function blocks
FF13
Alarm 2 Function blocks
FF14
Alarm 3 Function blocks
FF15
Alarm 4 Function blocks
FF16
Axis does not exist machine
data 1=0
FF17
Operating conditions do not
exist
FF18
OFF1 Missing
FF19
OFF2 Missing
FF20
OFF3 Missing
FF21
Enable Controller ENC Missing
FF22
Machine data 1 changed
FF23
Actual value disable not
allowed – axis stand still
FF24
Direction of movement not
allowed
FF25
Deceleration=0
FF26
Distance to go negative
FF27
Setup speed=0
FF28
Reference approach velocity
FF29
Reference point reducing=0
FF30
MDI Block number not allowed
8.5-58
MC error
MC alarm Error text /
F035
F036
F063
F148
F149
F150
F151
A002
A003
A014
A015
A016
A061
A062
A063
A064
A129
A130
A131
A132
A133
A134
A136
A145
A146
A148
A149
A160
A161
A162
A165
6SE7087-6QX70 (Version AD)
Compendium Motion Control
02.2004
description
External fault 1
External fault 2
PIN missing
Fault 1 function blocks
Fault 2 function blocks
Fault 3 function blocks
Fault 4 function blocks
SIMOLINK startup alarm
Drive not synchronous
Simulation active alarm
External alarm 1
External alarm 2
Alarm 1 function blocks
Alarm 2 function blocks
Alarm 3 function blocks
Alarm 4 function blocks
Axis does not exist, machine
data 1=0
Operating conditions not
fulfilled
OFF1 missing
OFF2 missing
OFF3 missing
No controller enable ENC
Machine data 1 (position
encoder type) changed, RESET
necessary
Actual value disabling illegal -
axis standstill
Direction of movement illegal
Deceleration=0
Distance to go negative
Set up velocity stage=0
Homing approach velocity=0
Homing creep velocity=0
MDI travel block number illegal
Siemens AG