Operation In Parameter Setting Mode - YASKAWA SGMAH User Manual

Sigma ii series servo system
Hide thumbs Also See for SGMAH:
Table of Contents

Advertisement

Sigma II User's Manual
7.1.6

Operation in Parameter Setting Mode

Functions can be selected or adjusted by setting parameters. There are two types of
parameters that can be set. One type requires value setting and the other requires
function selection. These two types use different setting methods.
With value setting, a parameter is set to a value within the specified range of the
parameter.
With function selection, the functions allocated to each digit of the
seven-segment LED panel indicator (five digits) can be selected.
See Appendix B List of Parameters.
Changing Parameter Settings
The parameter settings can be used to change parameter data. Check the permitted
range of the parameters in Appendix B List of Parameters , before changing the data.
The example below shows how to change parameter Pn507 from 100 to 85.
Using the Hand-held Digital Operator
1. Press the DSPL/SET key to select the parameter setting mode.
2. Select the parameter number to set. (Pn507 is selected in this example.)
Press the Left Arrow
selected digit will flash.
Press tthe Up Arrow
3. Press the DATA/ENTER key to display the current data for the parameter
selected at step 2.
4. Change the data as needed (to 85, in this example).
Press the Left Arrow
digit will flash.
Press the Up Arrow
Continue pressing the key until "00085" is displayed.
or Right Arrow
or Down Arrow
key to change the value.
or Right Arrow
key to select the digit. The selected
or Down Arrow
key to change the value.
7 - 8
Chapter 7: Using the Digital Operator
key to select the digit. The