cut off and the corresponding LED indicator will be updated. When the PD is disconnected from the PSE normally,
PSE will stop outputting power supply and update the corresponding LED indicator.
Disabled: Disable power supply. With the PSE power supply disabled, no power will be output regardless of the
existence of PD connections, which means the port will act as a regular Ethernet data port without affecting data
transmission.
When it is globally disabled, no power supply will be output regardless of the power supply is enabled or disabled on
ports.
Examples:
Disable power supply on ports1, 3, 4, 5, 6.
Switch(Config)# interface ethernet 1/0/1;3-6
Switch(Config-Port-Range)#no power inline enable
68.1.5 power inline high-inrush
Command:
power inline high-inrush enable
no power inline high-inrush enable
Function:
Enable the allowed high-inrush current when nonstandard PD is powered instantaneously, disable the allowed
high-inrush current.
Parameter:
None.
Command Mode:
Global mode
Default:
The allowed high-inrush current is not enabled.
Usage Guide:
high-inrush current will be brought when nonstandard PD is powered instantaneously, it will result PSE
self-protection to make PD power failure. Here, if this nonstandard PD must be powered, it needs to allow the
high-inrush current.