Guide to Feature Programming
Program
Number
10-09-01
14-02-05
14-02-11
21-01-04
21-01-05
Dial Tone Detection
Program Name
DTMF and Dial Tone Circuit Setup
Analog Trunk Data Setup – Dial
Tone Detection for Manually
Accessed Trunks
Analog Trunk Data Setup – Next
Trunk in Rotary if No Dial Tone
System Options for Outgoing
Calls – Dial Tone Detection Time
System Options for Outgoing
Calls – Disconnect Time When
Dial Tone Not Detected
Description/Comments
If dial tone detection is enabled, be
sure to allocate at least one circuit
for dial tone detection [ICM/Trunk
(0) or Trunk (2)].
Use this option enable/disable dial
tone detection for directly
accessed trunks. If disabled, the
system outdials on the trunks
without monitoring for dial tone.
If enabled, the system skips over a
trunk if dial tone is not detected.
This option pertains to calls placed
using Call Appearance (CAP)
Keys, Speed Dial, ARS, Last
Number Redial or Save Number
Dialed. It does not pertain to line
key or Direct Trunk Access calls.
If dial tone detection is enabled,
the system waits this time for the
Telco to return dial tone. When the
time expires, the system assumes
dial tone is not present. To disable
this time (and have the system
wait continuously), enter 0.
If 14-02-11 is enabled, the system
skips over a trunk if dial tone is not
detected. This option pertains to
calls placed using Speed Dial,
ARS, Last Number Redial or Save
Number dialed. It does not pertain
to line key or Direct Trunk Access
calls.
Issue 5.0
Assigned Data
0 = Common Use
1 = Extension Only
2 = Trunk Only
Default:
Circuit/Resource
01~08 = 1 (Extensions)
Circuit/Resource
09~32 = 2 (Trunks)
Circuit/Resource
33~96 = 0 (Not Used)
Circuit/Resource
97~160 = 0 (Common)
When PZ-BS10 is
installed, 97~160 are
available
0 = Dial Tone
Detection Not Used
1 = Dial Tone
Detection Used
(default = 0)
0 = Disable
1 = Enable
(default = 0)
0~64800 (seconds)
(default = 5 seconds)
0~64800 (seconds)
(default = 3 seconds)