Issue 5.0
Program
Number
80-04-06
80-04-07
80-04-08
80-04-09
Operation
None
1 - 94
Program Name
Call Progress Tone Detector
Setup – ON Minimum Time
Call Progress Tone Detector
Setup – ON Maximum Time
Call Progress Tone Detector
Setup – OFF Minimum Time
Call Progress Tone Detector
Setup – OFF Maximum Time
Description/Comments
Use this option to set the minimum
On time.
Use this option to set the
maximum On time.
Use this option to set the minimum
Off time.
Use this option to set the
maximum Off time.
UNIVERGE SV8100
Assigned Data
1~255 (30+30-
7680ms)
default:
Type 1 (DT) – 9
(300ms)
Type 2 (BT) – 9
(300ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 0
Type 2 (BT) – 14
(450ms) [ET]
Type 3 (RBT) – 40
1230ms)
Type 4, Type 5 – 0
1~255 (30+30-
7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 9
(300ms)
Type 3 (RBT) – 83
(2520ms)
Type 4, Type 5 – 0
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 14
(450ms)
Type 3 (RBT) – 115
(3480ms)
Type 4, Type 5 – 0
Automatic Release