UNIVERGE SV8100
Program
Number
16-02-01
22-02-01
22-07-01
Q-Sig
Program Name
Department Group Assignment
for Extensions
Incoming Call Trunk Setup –
Incoming Type
DID Assignment
Description/Comments
Assign the incoming trunk type for
each trunk.
If you want a trunk to be a DIL to a
Department Group, assign Service
Type 4 for each Night Service
Mode. Refer to Program 22-07-01.
For each trunk assigned Service
Type 4 in Program 22-02-01
above, assign the DIL destination
as the Department Group pilot
number (as assigned in Program
11-07-01).
Issue 5.0
Assigned Data
Department Groups
1-64
Priority 1-512
Default = All
extensions in
Department Group 1
with priority in port
order:
Port 1 priority = 1
Port 512 priority = 512
0 = Normal
1 = VRS (second dial
tone if no VRS
installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode
Switching
(default = 0)
Extension Number
(maximum eight digits)
(default not assigned)
1 - 815

Hide quick links: