NEC UNIVERGE SV8100 Features & Specifications Manual page 639

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Programming Flowchart of ISDN-PRI – Placing Calls
ISDN Compatibility
In 10-03-01, determine the mode of the DTI( )-U40 ETU
In 10-03-03, enter
'0'.
In 10-03-04, select the Layer 3 timer type (1-5). The timer value is
In 10-03-06, determine the length of cable used to connect from the CSU to
(0=0-40m, 1=40-81m, 2=81-122m, 3=122-162m, 4=162-200m).
In 10-03-08, enter
'0'.
In 20-08-02, enter 0 to
No
disable outgoing calls.
In 20-06-01, assign
Class of Service to extensions.
Stop
In 20-08-13, enter 0 to
disable calling number
No
display by telco.
In 20-13-31, enter
0 to disable trunk
No
ID display by telco.
Start
(0=not set, 1=T-Bus)
Is the CRC
Multi-Frame
No
(CRC4)
used?
set up in Program 81-06 (T-Bus)
CD-PRTA
the DTI( )-U40 ETU
Is the Dial
Sending Mode
Enblock
Enblock or
Overlap
Sending?
Should system users be able to place
outgoing calls on trunks?
Should telco display the
calling number for outgoing
calls?
Should telco display the
trunk identification for
outgoing calls the extension
places?
Go To
A
CD-PRTA
In 10-03-03, enter
Yes
'1'.
In 10-03-08, enter
Overlap
'1'.
In 10-03-09, select either
Keypad Facility (0) or
Called Party Number (1) for
the dial information element.
20-08-02, enter '1' to
Yes
enable outgoing
calls.
In 20-08-13, enter 1 to
Yes
enable calling number
display by telco.
In 20-13-31, enter
Yes
1 to enable trunk
ID display by telco.
Issue 5.0
1 - 629

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents