NEC UNIVERGE SV8100 Features & Specifications Manual page 539

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Number
24-01-06
24-02-03
24-02-04
25-07-02
25-07-03
25-07-07
25-07-08
25-07-09
Flexible Timeouts
Program Name
System Options for Hold – Park
Hold Time - Normal
System Options for Transfer –
Delayed Call Forwarding Time
System Options for Transfer –
Transfer Recall Time
System Timers for VRS/DISA –
VRS/DISA No Answer Time
System Timers for VRS/DISA –
Disconnect after VRS/DISA
retransfer to IRG
System Timers for VRS/DISA –
Long Conversation Warning
Tone Time
System Timers for VRS/DISA –
Long Conversation Disconnect
Time
System Timers for VRS/DISA –
DISA Internal Paging Time
Description/Comments
Set the Park Hold Time (0~64800
seconds). A call that is parked
longer than the programmed
interval recalls the extension
where it was initially parked.
Refer to
Flexible System
Numbering on page 1-501
for
setting Flexible Timeouts for Class
of Service.
Set the Delayed Call Forwarding
interval. For an unanswered call,
Call Forward No Answer occurs
after this interval.
Set the Transfer Recall Time. An
unanswered transferred call
recalls to the extension that
initially transferred it after this
interval. This time also sets how
long a transferred call camps-on to
a busy extension.
A VRS/DISA caller can ring an
extension for this time before the
system sets the call as a Ring No
Answer. After this time expires, the
call follows the programmed Ring
No Answer routing (set in Program
25-03 and Program 25-04).
Define the system timers which
affect DID and DISA after VRS/
DISA retransfer to IRG.
Determine the time a DISA caller
or any trunk-to-trunk (such as
Tandem Trunking) conversation
can talk before the Long
Conversation tone is heard.
This time determines how long the
system waits before disconnecting
a DISA caller or any trunk-to-trunk
(such as Tandem Trunking)
conversation call after the Long
Conversation tone is heard.
This is the maximum length of an
Internal Page placed by a DISA
caller. If the Page continues longer
than this time, the system
terminates the DISA call.
Issue 5.0
Assigned Data
0~64800 (seconds)
(default = 90 seconds)
0~64800 (seconds)
(default = 10)
0~64800 (seconds)
(default = 30)
0~64800 (seconds)
(default = 0 seconds)
0~64800 (seconds)
(default = 60 seconds)
0~64800 (seconds)
(default = 3600
seconds)
0~64800 (seconds)
(default = 10 seconds)
0~64800 (seconds)
(default = 30 seconds)