NEC UNIVERGE SV8100 Features & Specifications Manual page 102

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 5.0
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Guide to Feature Programming
Program
Number
14-02-09
14-02-14
80-04-01
1 - 92
Program Name
Analog Trunk Data Setup – Busy
Tone Detection
Analog Trunk Data Setup – Loop
Start/Ground Start
Call Progress Tone Detector
Setup – Detection Level
Description/Comments
This option enables/disables Busy
Tone Detection.
This option identifies the analog
trunk as either loop or ground
start.
Use this option to set the
Detection Level.
UNIVERGE SV8100
Assigned Data
0 = Disable (No)
1 = Enable (Yes)
(default = 0)
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
(default = 0)
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
Automatic Release