NEC UNIVERGE SV8100 Features & Specifications Manual page 711

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Number
15-22-04
20-01-16
20-31-24
20-31-25
21-12-01
21-13-01
22-01-12
Mobile Extension
Program Name
Mobile Extension Setup -
Callback
System Options - Mobile
Extension Callback Duration
Time
Timer Class Timer Assignment -
Answer from Mobile Extension
Timer Class Timer Assignment -
Mobile Extension Callback
Duration Time
ISDN Calling Party Number
Setup for Trunks
ISDN Calling Party Number
Setup for Extensions
System Options for Incoming
Calls - Answer Time from Mobile
Extension
Description/Comments
Select if callback to Cell Phone is
required
Set up the system callback
duration time for the ring target in
Mobile Extension
This program defines the data
corresponding to program 22-01-
12. Refer to Timer Class for
Extension.
This program defines the data
corresponding to Program 22-01-
12. Refer to Timer Class for
Extension.
Assign Calling Party Numbers for
each trunk (maximum 16 digits per
entry). When a call is made by an
extension which does not have an
Extension Calling Number
assigned (Program 21-13), the
system sends the calling number
for the ISDN trunk defined in
21-12. If the Calling Party Number
is assigned in both Program 21-12
and Program 21-13, the system
sends the data in Program 21-13.
Assign each extension a Calling
Party Number (maximum 16 digits
per entry). The calling number is
the subscriber number of the
dial-in number. When a call is
made by an extension which does
not have an Extension Calling
Number assigned (Program
21-12), the system sends the
calling number for the ISDN trunk
defined in Program 21-13. If a
Calling Party Number is assigned
in both Program 21-12 and
Program 21-13, the system sends
the data in Program 21-13.
Set up the system answering time
when receive an incoming call
from target Mobile extension.
Issue 5.0
Assigned Data
0 = no callback
1 = callback
(default: 0)
0~64800 seconds
(default = 15 seconds)
0 = Immediate Answer
1~64800 seconds
(default = 3 seconds)
1~64800 seconds
(default = 15 seconds)
(maximum 16 digits)
*
#
1-0,
,
Default:
(All trunks = No setting)
*
#
0~9,
,
(Maximum 16 digits)
(default not assigned)
0 = Immediate Answer
1~64800 seconds
(default = 3 seconds)
1 - 701