NEC UNIVERGE SV8100 Features & Specifications Manual page 803

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Number
14-07-01
15-01-02
15-02-10
15-06-01
21-02-01
Prime Line Selection
Program Name
Trunk Access Map Setup – Trunk
Port Number
Basic Extension Data Setup –
Outgoing Trunk Line Preference
Multiline Telephone Basic Data
Setup – Ringing Line Preference
for Trunk Calls
Trunk Access Map for
Extensions
Trunk Group Routing for
Extensions
Description/Comments
For outgoing Prime Line selection,
assign each Prime Line trunk to a
different Access Map and deny
outbound access to all trunks
except the Prime Line trunk.
Turn On (1) or Off (0) Outgoing
Trunk Line Preference for
extensions.
Enter 1 if lifting the handset should
answer ringing Prime Line; enter 0
to seize idle line appearance.
Set assignment so extension(s)
can have access to Prime Line.
Deny outbound access to
extensions that should not have
Prime Line.
Assign extension(s) to a Prime
Line route for outgoing Prime Line
access.
Issue 5.0
Assigned Data
0 = No access
1 = Outgoing access
only
2 = Incoming access
only
3 = Access only when
trunk on Hold
4 = Outgoing access
and access when trunk
on Hold
5 = Incoming access
and access when trunk
on Hold
6 = Incoming and
Outgoing access
7 = Incoming access,
outgoing access and
access when trunk
on Hold
Trunk Access Maps:
1~200
Default:
Access Maps 1~200 =
Trunk Ports 1~200
assigned with option 7
access (incoming and
outgoing access and
access when trunk is
on Hold)
0 = Off
1 = On
(default = 0)
0 = Idle (Off)
1 = Ringing (On)
(default = 1)
Trunk Access Maps:
1~200
(default = 1)
Trunk Groups: 1~100
Day/Night Mode: 1~8
Route Table Number:
0~100
(0 = No Setting)
(default = 1)
1 - 793