Program
Number
20-09-01
20-09-07
20-11-12
20-13-05
20-13-06
24-02-07
1 - 168
Program Name
Class of Service Options
(Incoming Call Service) –
Second Call for DID/DISA/DIL/
E&M Override
Class of Service Options
(Incoming Call Service) – Call
Queuing
Class of Service Options (Hold/
Transfer Service) – Call
Forwarding Off-Premise
(External Call Forwarding)
Class of Service Options
(Supplementary Service) –
Intercom Off-Hook Signaling
Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
Description/Comments
Turns Off (0) or On (1) the
extension ability to receive a
second call from a DID, DISA, DIL,
or tie line caller.
.
With this option set to 1, the
destination extension must
be busy for a second DNIS
caller to ring through. If the
destination extension does
not have a trunk or CAP key
available for the second call
and a previous call is ringing
the extension but has not yet
been answered, the second
caller hears busy regardless
of this program setting.
Turn Off (0) or On (1) an extension
ability to have calls queued if a call
rings the extension when it is busy.
In an extensions Class of Service,
turn On (1) or Off (0) setting up
Call Forwarding Off-Premise at the
extension.
Turn On (1) or Off (0) the ability of
an extension to receive Off-Hook
Signals.
Allows a busy extension ability to
manually (0) or automatically (1)
receive Off-Hook signals.
Timer starts when a trunk begins
talking with another trunk (for
example: Trunk-to-Trunk Transfer,
outgoing from trunk, Tandem
Trunking). When this time expires,
a warning tone is heard.
Call Forwarding, Off-Premise
UNIVERGE SV8100
Assigned Data
0 = Off
1 = On
(default = 1 for
COS 1~15)
0 = Off
1 = On
(default = 1 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Off
1 = On
(default = 1 for
COS 1~15)
0 = Off
1 = On
(default = 1 for
COS 1~15)
0~64800 (seconds)
(default = 1800
seconds)