16) Remove the 2 cable fixing screws [2] of the No. 1 mirror base [1].
17) Remove the cable fixing screws [3].
18) Free the 2 hooks [4] of the cable from the right side of the reader unit
frame.
19) Detach the cable for the pulleys.
[2]
[3]
5.4.12.12 Fitting the Scanner Drive Cable
1) Put the ball of the cable into the hole of the drive pulley [1], and wind
the cable (4 times inside; 5 times outside); then, tape it in place. At
this time, make sure that the cable fixing [2] is on the inside.
2) Fit the cable on the pulleys; then, fit one end on the left side hook [3]
and the other end on the right side hook [4].
3) Temporarily fix the cable fixing plate [2] in place on the No. 1 mirror
base [5].
4) Mount the reader unit upper frame.
[1]
[4]
[4]
[2]
F-5-152
0008-7880
[2]
[3]
[3]
5.4.12.13 Adjusting the Position of the No. 1/No. 2 Mirror
Base
1) Arrange the mirror positioning tool (FY9-3009-040) so that it is ready
Chapter 5
[1]
[1]
[4]
[5]
[4]
[2]
F-5-153
[4]
[5]
[4]
F-5-154
0008-7881