CHAPTER 5 MAINTENANCE AND INSPECTION
8) Slide out the scanner motor unit [5] to
the front, and detach the belt; then, de-
tach the scanner motor unit.
When mounting it, set the ten-
sion of the belt to 10 ±2N
REF.
(1 ±0.2 kgf).

5.2.2 Scanner Drive Cable

a. Adjusting the Tension of the Scanner Drive Cable
When routing the scanner drive cable, be
sure to have a mirror positioning tool (FY9-
3040-000) ready.
1) Remove the ADF.
2) Remove the right glass retainer.
3) Remove the copyboard glass.
4) Open the front cover, and remove the
inside upper cover and the inside cover
(AP kit).
5) Remove the control panel.
6) Remove the rear cover and the rear up-
per cover.
7) Remove the inverter PCB unit.
8) Move the No. 1 mirror base to where
the cable fixing [1] of the No. 1 mirror
base is in view through the hole in the
machine side plate.
5-28
COPYRIGHT© 2001 CANON INC.
F05-502-03
[1]
Front
F05-502-04
[1]
Rear
F05-502-05
2000 2000 2000 2000