DIAGNOSTIC PROCEDURE WITH DIAGNOSTIC TROUBLE CODE (DTC)
ENGINE (DIAGNOSTICS)
BX:DTC P1090 — TUMBLE GENERATOR VALVE SYSTEM #1 (RH) MALFUNC-
TION (STUCK OPEN) —
• DTC DETECTING CONDITION:
• Immediately at fault recognition
CAUTION:
After repair or replacement of faulty parts, conduct Clear Memory Mode <Ref. to EN(TURBO)-45, OP-
ERATION, Clear Memory Mode.> and Inspection Mode <Ref. to EN(TURBO)-42, Inspection Mode.> .
Step
1
CHECK ANY OTHER DIAGNOSTIC TROU-
BLE CODE (DTC) ON DISPLAY.
2
CHECK TUMBLE GENERATOR VALVE RH
1)Remove the tumble generator valve assem-
bly.
2)Check the tumble generator valve body.
BY:DTC P1091 — TUMBLE GENERATOR VALVE SYSTEM #1 (RH) MALFUNC-
TION (STUCK CLOSE) —
• DTC DETECTING CONDITION:
• Immediately at fault recognition
CAUTION:
After repair or replacement of faulty parts, conduct Clear Memory Mode <Ref. to EN(TURBO)-45, OP-
ERATION, Clear Memory Mode.> and Inspection Mode <Ref. to EN(TURBO)-42, Inspection Mode.> .
Step
1
CHECK ANY OTHER DIAGNOSTIC TROU-
BLE CODE (DTC) ON DISPLAY.
2
CHECK TUMBLE GENERATOR VALVE RH
1)Remove the tumble generator valve assem-
bly.
2)Check the tumble generator valve body.
Check
Is any other DTC displayed?
Does the tumble generator
valve move smoothly? (No dirt
or foreign materials clogged)
Check
Is any other DTC displayed?
Does the tumble generator
valve move smoothly? (No dirt
or foreign materials clogged)
EN(TURBO)-278
Yes
Inspect the rele-
Go to step 2.
vant DTC using
"List of Diagnostic
Trouble Code
(DTC)" <Ref. to
EN(TURBO)-75,
List of Diagnostic
Trouble Code
(DTC).>
Replace the tum-
Clean the tumble
ble generator
generator valve.
valve assembly.
<Ref. to
FU(TURBO)-41,
Tumble Generator
Valve Assembly.>
Yes
Inspect the rele-
Go to step 2.
vant DTC using
"List of Diagnostic
Trouble Code
(DTC)" <Ref. to
EN(TURBO)-75,
List of Diagnostic
Trouble Code
(DTC).>
Replace the tum-
Clean the tumble
ble generator
generator valve.
valve assembly.
<Ref. to
FU(TURBO)-41,
Tumble Generator
Valve Assembly.>
No
No