FUEL INJECTION (FUEL SYSTEMS)
10) Tighten the two bolts which install fuel pipes on
the left side of intake manifold.
Tightening torque:
4.9 N·m (0.5 kgf-m, 3.6 ft-lb)
11) Connect the evaporation hoses to purge valve.
CAUTION:
Carefully connect the evaporation hoses.
(B)
(A)
(D)
(A) To fuel pipe ASSY
(B) To intake duct
(C) To purge control solenoid valve
(D) To intake manifold
INTAKE MANIFOLD
EN0805
(C)
EN0816
FU(TURBO)-26
12) Connect the evaporation hose to intake mani-
fold.
13) Install the purge control solenoid valve.
Tightening torque:
16 N·m (1.6 kgf-m, 11.8 ft-lb)
14) Connect the hoses to purge control solenoid
valve.
CAUTION:
Carefully connect the evaporation hoses.
(A)
(A) To intake manifold
(B) To purge valve
EN0803
EN0802
(B)
EN0817