System Monitoring And Troubleshooting; Environmental Information; Example - Alcatel-Lucent OmniAccess 700 Cli Configuration Manual

Release versions: 2.2, 2.2-r02, 2.3
Hide thumbs Also See for OmniAccess 700:
Table of Contents

Advertisement

S
M
YSTEM
ONITORING AND
E
I
NVIRONMENTAL
NFORMATION
The show environment command displays the latest known sensor readings
from the occupied slots that contain line cards or switch cards. The standard
readings are the temperature from the card and voltage readings taken at various
places on the card. The sensor readings are monitored to ensure that they are
within the defined ranges and if not, the card may be powered down.
The command can show individual card readings, or display the readings for all
occupied slots. For each slot displayed, the report includes the slot number and
card type, last time the card's sensors were reported, and the values of the
temperature and various reference voltages on that card.
The sensor readings are monitored to ensure that they are within safe operating
ranges, and if not, the card may be powered down (see section
Individual
Slots"). Any deviation will be noted in the log.
Command (in SUM)
show environment [slot <0-7>|
<24-25>]
E
XAMPLE
ALU> show environment
Chassis environment readings
Report generated at Wed May 14 06:18:32 2008
Chassis temperature: 41C
SE - Services engine
Slot number 7
Liveness failures will report once
PCI configuration status: Ready
Reported at Wed May 14 06:18:28 2008 (4 seconds ago)
Temperature reading:
Opteron temperature : 46.0C
Opteron status : Active
Voltage reading:
SC - Switch card
Slot number 24
Liveness failures will report once
PCI configuration status: Ready
Reported at Wed May 14 06:18:31 2008 (1 seconds ago)
Temperature reading:
Voltage reading:
2.50V(0%)
CLI Configuration Guide
Beta
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)

System Monitoring and Troubleshooting

T
ROUBLESHOOTING
This command shows the environmental
state of the various parts and modules in
the system.
31.500C
4.91V(-1%)
1.25V(-3%)
40.500C
11.68V(-2%)
3.26V(-1%)
Alcatel-Lucent
"Managing
Description
2.49V(0%)
1.28V(0%)
Beta
108

Advertisement

Table of Contents
loading

Table of Contents