Managing Individual Slots; Example - Alcatel-Lucent OmniAccess 700 Cli Configuration Manual

Release versions: 2.2, 2.2-r02, 2.3
Hide thumbs Also See for OmniAccess 700:
Table of Contents

Advertisement

Left running head:
Chapter name (automatic)
System Configuration and Monitoring
M
I
ANAGING
NDIVIDUAL
The power command allows the privileged user to control the power of slots 0-7
on the OA-780 and slots 0-1 on the OA-740. Powering down an occupied slot is
almost equivalent to physically removing the card from the chassis.
Individual cards within the chassis may be managed separately by controlling
their power. This may happen internally if a card is malfunctioning or has
exceeded permissible environmental limits. A card may also be powered down
manually using the CLI.
A slot may be powered down using the CLI power command, or it may have been
powered down by some other means, such as a sensor reading that exceeds the
defined range of operation. Once a slot is powered down, some form of
intervention is required to power it back. The power command can be used to
power it back. Alternatively, the card can be physically removed from the slot for a
few seconds, then re-inserted, or the entire chassis can be power cycled.
There are four forms of manual intervention:
1. Physically power cycle the entire chassis.
2. Reload the entire chassis.
3. Remove the card from its slot for 10 seconds or more and re-insert it, or
4. Use the CLI to power up the slot.
Command (in SUM)
power slot <slot-number>
{up|down}
E
XAMPLE
ALU# power slot 1 down
ALU# power slot 1 up
107
Beta
S
LOTS
Alcatel-Lucent
Description
This command powers down a slot or
attempts to power it up again if the slot
has already been powered down.
This command controls the power of slot
0-7 on the OA-780 and slot 0-2 on the
OA-740.
CLI Configuration Guide
Beta

Advertisement

Table of Contents
loading

Table of Contents