Mlfr Configuration Steps - Alcatel-Lucent OmniAccess 700 Cli Configuration Manual

Release versions: 2.2, 2.2-r02, 2.3
Hide thumbs Also See for OmniAccess 700:
Table of Contents

Advertisement

MLFR C
ONFIGURATION
This section lists the instructions to be followed while configuring MLFR.
Note:
The following MLFR configuration commands are shown for a T1 interface as an
example. The steps are similar for configuration of MLFR on an E1 interface.
Step 1: Enter Configuration Mode
Step 2: Configure T1 controller
Step 3: Configure the channel-group on the controller before entering the
Interface Configuration Mode. This command creates a channel-group that will
form a channelized serial interface.
Note:
Creation of a channel-group is a pre-requisite for configuring a Serial Interface on a T1
or an E1 controller.
Step 4: Administratively bring up the controller.
Step 5: Exit from the controller mode
Note:
The above steps can be skipped if the T1 or E1 controller has already been
configured. For more details on configuring a T1 or an E1 controller, refer to the
Line Card"
chapter.
The above steps can also be skipped if you are configuring MLFR on a Serial
interface (V.35/X.21). The steps (Step 6 - Step 16) hold good for configuration of
MLFR on V.35/X.21 interface, except that there is no channel group number in the
interface name. Configure a serial interface using the following command:
ALU(config)# interface Serial <slot/port>
ALU(config-if Serial<slot/port>)#
CLI Configuration Guide
Beta
S
TEPS
ALU# configure terminal
ALU(config)#
ALU(config)# controller T1 <slot/port>
ALU(config-controller T1)#
ALU(config-controller T1)# channel group <0-23>
timeslots <1-24> speed [56K|64K]
ALU(config-controller T1)# no shutdown
ALU(config-controller T1)# exit
ALU(config)#
Alcatel-Lucent
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
MLFR Configuration
"T1E1
365
Beta

Advertisement

Table of Contents
loading

Table of Contents