Clock Synchronize; Example - Alcatel-Lucent OmniAccess 700 Cli Configuration Manual

Release versions: 2.2, 2.2-r02, 2.3
Hide thumbs Also See for OmniAccess 700:
Table of Contents

Advertisement

C
S
LOCK
YNCHRONIZE
The clock synchronize command establishes how, from where, and how often the
chassis should synchronize its time with an external source.
There are three elements to the specification:
Protocol
This is the protocol to be used. Most common is the NTP protocol. Another
option is the more basic rdate. It is desirable to synchronize the system time
from the RTC.
Server
The address of the server that is used as the external time source. This is
valid only for NTP and RDATE protocols.
Rate
The rate at which the synchronization should be performed. Typically, the
settings are in the multi-hour range. The default value for the rate is every 12
hours.
Command (in SUM)
clock synchronize [{using
{ntp|rdate|rtc}] [server
<name>] [every <number>
{hours|minutes}]
Note:
1. Server name is mandatory for ntp and rdate protocols.
2. The parameter "number" depicts the number of minutes or hours between
updates.
3. The server name can be specified either in dotted numeric or domain name
format.
E
XAMPLE
ALU(config)# clock synchronize using ntp server 10.91.2.87
every 2 hours
This command has no output. To verify the settings, use the 'show clock'
command described in this section.
CLI Configuration Guide
Beta
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
Setting and Displaying the System Time and Date
This command establishes how the
chassis should synchronize its time with
an external source.
Alcatel-Lucent
Description
Beta
80

Advertisement

Table of Contents
loading

Table of Contents