Lfi - Mlppp Configuration Steps; Lfi Configuration On Mlppp - Alcatel-Lucent OmniAccess 700 Cli Configuration Manual

Release versions: 2.2, 2.2-r02, 2.3
Hide thumbs Also See for OmniAccess 700:
Table of Contents

Advertisement

LFI - MLPPP C
ONFIGURATION
This section lists the commands for LFI configuration on MLPPP interface.
Note:
Configuring channelized serial interface on T1 or E1 controller and configuring
MLPPP interface is a pre-requisite to LFI configuration on a MLPPP interface.
The following MLPPP configuration commands are shown for a T1 interface as an
example. The steps are similar for configuration of MLPPP on an E1 interface.
For more details on T1 or an E1 controller configuration, refer to the
chapter, and refer to
Step 1: Enter Configuration Mode
Step 2: Configure T1 Controller
Step 3: Configure the channel-group on the controller before entering the
Interface Configuration Mode. This command creates a channel-group that forms
a channelized serial interface.
Note:
Creation of a channel-group is a pre-requisite for configuring a Serial Interface on a T1
or an E1 controller.
Step 4: Administratively bring up the controller.
Step 5: Exit from the controller mode
CLI Configuration Guide
Beta
S
TEPS
"Multilink Point to Point Protocol"
ALU# configure terminal
ALU(config)#
ALU(config)# controller T1 <slot/port>
ALU(config-controller T1)#
ALU(config-controller T1)# channel group <0-23>
timeslots <1-24> speed [56K|64K]
ALU(config-controller T1)# no shutdown
ALU(config-controller T1)# exit
ALU(config)#
Alcatel-Lucent
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)

LFI Configuration on MLPPP

for MLPPP configuration.
"T1E1 Line Card"
381
Beta