10
Self-generated certificates
You can also create and import all of the required certificates
yourself.
Self-generated certificates must fulfill the following requirements:
General requirements
File format: *.der
Signature with hash SHA256
Validity period, 5 years max. is recommended
Client certificates
Host name of the client
Application URI of the client
Server certificates
Host name of the control
Application URI of the server according to the following
structure:
urn:<hostname>/HEIDENHAIN/OpcUa/NC/Server
Validity period of 20 years maximum
468
HEROS functions | OPC UA NC Server (options 56 to 61)
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022