Tools | Tool carrier management
Parameterizing tool carrier templates in Programming operating
mode
Proceed as follows to parameterize tool carrier templates and save
these parameters:
Press the Programming key
Press the PGM MGT key
Select the path TNC:\system\Toolkinematics
Select the tool carrier template
The control opens the additional
ToolHolderWizard tool with the selected tool
carrier template.
The cursor goes to the first parameterizable
value.
Adjust values
Enter the name for the parameterized tool holder
in the Output file area
Press the GENERATE FILE button
If required, reply to the message on the control
Press the CLOSE icon
The control closes the additional tool
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
4
163