6
Block scan to the first start-up point:
Press the BLOCK SCAN soft key
Enter the first NC block where you wish to start
Press the ADVANCED soft key if needed
If required, press the SELECT LAST BLOCK soft
key in order to select the last saved interruption
Press the NC Start key
The control starts the block scan and calculates
until the entered NC block.
If the control should restore the machine status of the entered NC
block:
Press the NC Start key
The control restores the machine status (e.g.,
TOOL CALL, M functions).
If the control should restore the axis positions:
Press the NC Start key
The control moves in the specified sequence to
the specified positions.
If the control should run the NC block:
Select the Program Run Single Block operating
mode if required
Press the NC Start key
The control runs the NC block.
Block scan to the next start-up point:
Press the CONTINUE BLOCK SCAN soft key
Enter the NC block where you wish to start
If you changed the machine status:
Press the NC Start key
If you changed the axis positions:
Press the NC Start key
If the control should run the NC block:
Press the NC Start key
Repeat these steps if required to jump to the next
start-up point
Press the NC Start key
The control resumes execution of the NC
program.