HEIDENHAIN TNC 620 User Manual page 344

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

9
9.4
Loading the machine configuration
Application
Caution: Data may be lost!
The RESTORE function irrevocably overwrites the current machine
configuration with the backup files. The control does not perform
an automatic backup before the RESTORE function is executed.
The current files are thus permanently lost.
Perform a backup of the current machine configuration prior to
the RESTORE function
Use the function only in consultation with the machine tool
builder
Your machine tool builder can provide you with a backup including
a machine configuration. After entering the RESTORE keyword, you
can restore the backup on your machine or programming station.
To restore a backup, proceed as follows:
Select the Code-number entry MOD function
Enter the RESTORE keyword
Press the OK soft key
Select the backup file in the control's file manager
(e.g., BKUP-2013-12-12_.zip)
The control opens the pop-up window for the backup.
Press Emergency Stop
Press the OK soft key
The control starts restoring the backup.
344
NOTICE
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
MOD functions | Loading the machine configuration

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 620 eTnc 620 programming station

Table of Contents