HEIDENHAIN TNC 620 User Manual page 406

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

10
Set protocol
(protocol no. 106702)
The communications protocol controls the data flow of a serial
transmission.
Please note:
The BLOCKWISE setting designates a type of data
transfer in which the data is transferred grouped in
blocks.
The BLOCKWISE setting does not correspond to
the data reception in blocks and the simultaneous
execution of older controls in blocks. This function is
no longer available for current controls.
Setting
Data transmission protocol
STANDARD
Standard data transmission
Line-by-line transmission
BLOCKWISE
Packet-based data transfer
RAW_DATA
Transfer without protocol
Transmission of characters only
Set data bits
(dataBits no. 106703)
By setting the data bits you define whether a character is transmitted
with 7 or 8 data bits.
Check parity
(parity no. 106704)
The parity bit defines whether transmission errors are checked.
The parity bit can take three different forms:
Setting
Meaning
NONE
No parity
There is no error detection.
EVEN
Even parity
There is an error if the receiver detects an uneven
number of bits in his evaluation.
ODD
Odd parity
There is an error if the receiver detects an even
number of bits in his evaluation.
Set stop bits
(stopBits no. 106705)
The start bit and one or two stop bits enable the receiver to
synchronize each transmitted character during serial data
transmission.
406
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
HEROS functions | Setting up data interfaces

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 620 eTnc 620 programming station

Table of Contents