HEIDENHAIN TNC 620 User Manual page 447

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

HEROS functions | User administration
HEROS role name
NC.EditTableAdv
HEROS.SetTimezone
HEROS.SetShares
HEROS.MountShares
HEROS.SetNetwork
HEROS.BackupUsers
HEROS.BackupMachine
HEROS.UserAdmin
HEROS.ControlFunctions
HEROS.SWUpdate
HEROS.VMSharedFolders
NC.RemoteProgramRun
NC.ConfigUserAdv
NC.Data.AccessServiceRead
Enabling Autologin
When the Autologin function is enabled, during startup the control
automatically activates a user defined by you, without the need to
enter a password.
As opposed to the Legacy-Mode, this enables you to restrict a user's
rights without entering a password.
For further authorizations, the control still requires an authentication
to be entered.
In order to enable Autologin, the following requirements must be
met:
User administration has been configured
The user for Autologin has been defined
Proceed as follows to enable the Autologin function:
Call the user administration
Select the Settings tab
Press the Global settings soft key
Tick the check box for Enable autologin
The control opens a window for selecting the user.
Select the user
Enter the user's password
Press the OK soft key
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
Description
Additional table programming functions (e.g., editing of the table head)
Adjustment of date and time, time zone and time synchronization via NTP and the
HEROS menu.
Configuration of public network drives mounted on the control
Connecting and disconnecting network shares with the control
Configuration of network and relevant settings for data security
Data backup on the control—for all users configured on the control
Backup and restoring data of the entire machine configuration
Configuration of user administration on the control
This includes creating, deleting and configuring local users
Control function of the operating system
Auxiliary functions, such as starting and stopping NC software
Telemaintenance
Advanced diagnostic functions, such as log data
Installation of software updates for the control
Access to shared folders of a virtual machine
Only relevant when running a programming station within a virtual machine
NC program start from an external application, e.g. via the DNC interface
Configuration access to the contents that have been enabled through code
number 123
Read-only access to the PLC: drive during servicing
10
447

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 620 eTnc 620 programming station

Table of Contents