HEROS functions | Ethernet interface
Examples of Mounting options
Enter options without a space, only separated by a comma
Options for NFS
Example
Meaning
rsize=8192
Packet size in bytes for data reception
Input range 512 to 8192
wsize=4096
Packet size in bytes for data transmission
Input range 512 to 8192
soft,timeo=3
Conditional Mount
Time in tenths of a second after which the control
will repeat the attempt
sec=ntlm
Authentication method ntlm
Use this option if the control displays the Permis-
sion denied error message upon connecting.
nfsvers=2
Protocol version
Options for SMB
Example
Meaning
domain=xxx
Name of the domain
HEIDENHAIN recommends not to write the
domain into the user name, but as an option.
vers=2.1
Protocol version
To avoid security gaps, prefer the current versions of the
SMB and NFS protocols.
Depending on the software status of the control, the
network drive may require an older protocol version.
In this case, you may change the protocol version with
the vers= auxiliary parameter. Contact your network
specialist.
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022