HEIDENHAIN TNC 620 User Manual page 360

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

9
Touch probe with radio transmission configuration
In the Set up touch probes MOD function, the control displays
information on each touch probe at the right-hand side of the screen.
Some of this information is also visible and configurable for infrared
touch probes.
Tab
TS 3-D touch probe
Work data
Data from the touch probe table
Project infor-
Connection data and diagnostics functions
mation
You can change the data from the touch probe table by selecting the
row with the cursor and overwriting the current value.
You can change the machine parameters only after first entering the
code number.
Changing properties
To change the characteristics of a touch probe, proceed as follows:
Place the cursor on the row for the touch probe
Select the "Properties" tab
The control shows the properties of the selected touch probe.
Change the properties as desired per soft key
You have the following options depending on the row on which the
cursor is located:
Soft key
Function
Select the probe signal
Select the radio channel
Select the channel with the best radio transmis-
sion and pay attention to overlaps with other
machines or wireless handwheels.
Change the radio channel
Delete the touch probe data
The control deletes the entry from the MOD
function and the touch probe table or from the
machine parameters.
Save a new touch probe in the current row
The control automatically overwrites the serial
number of the replaced touch probe with the new
number.
360
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
MOD functions | Setting up touch probes
TT tool touch probe
Data from the machine parameters
Connection data and diagnostics functions