HEIDENHAIN TNC 620 User Manual page 358

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

9
Setting up a touch probe with radio transmission
Refer to your machine manual.
In order for the control to recognize the touch probe with
radio transmission, you will require an SE 661 transceiver
with EnDat interface.
In the Set up touch probes MOD function, the left-hand side of the
screen shows the touch probes that have already been configured.
If not all of the columns are visible, you can shift the view with the
scroll bar or move the dividing line between the left and right sides of
the screen using the mouse.
To set up a new wireless touch probe, proceed as follows:
Place the cursor on the row of the SE 661
Select the radio channel
Press the CONNECT NEW TCH PROBE soft key
The control displays the next steps in the dialog
Follow the instructions in the dialog:
The control connects to the touch probe and
creates a new row in the table
Setting up a touch probe from within the MOD function
You can set up a 3-D touch probe with cable or with infrared
transmission either in the touch probe table, in tool management, or
in the Set up touch probes MOD function.
You can also define tool touch probes via the machine parameter
CfgTT (No. 122700).
In the Set up touch probes MOD function, the left-hand side of the
screen shows the touch probes that have already been configured.
If not all of the columns are visible, you can shift the view with the
scroll bar or move the dividing line between the left and right sides of
the screen using the mouse.
Setting up a 3-D touch probe
To set up a new touch probe, proceed as follows:
Press the CREATE TS ENTRY soft key
The control creates a new row in the table.
If necessary, highlight the row with the cursor
Enter the touch probe data on the right side
The control saves the entered data in the touch
probe table.
358
Remove the battery from the touch probe
Insert the battery into the touch probe
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022