Setup | Preset management
Manually saving the presets in the preset table
Proceed as follows in order to save presets in the preset table:
Select the Manual operation mode
Move the tool slowly until it touches (scratches)
the workpiece surface, or position the measuring
dial correspondingly
Press the PRESET MANAGEMENT soft key
The control opens the preset table and positions
the cursor in the line of the active preset.
Press the CHANGE PRESET soft key
The control displays all available input options in
the soft-key row.
Select the line in the preset table that you want to
change (the line number is the preset number)
If needed, select the column in the preset table
that you want to change
Use the soft keys to select one of the available
input options
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022