HEIDENHAIN TNC 620 User Manual page 147

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

Tools | Tool data
Column
Meaning
Maximum feed rate override that occurred
OVRMAX
during machining. The control enters the
value 100 (%) during the test run
Minimum feed rate override that occurred
OVRMIN
during machining. The control enters the
value -1 during the test run
0: The tool number is programmed
NAMEPROG
1: The tool name is programmed
The control saves the tool usage times in a separate file with the
extension pgmname.H.T.DEP. This file is not visible unless the
machine parameter dependentFiles (no. 122101) is set to MANUAL
There are two ways to run a tool usage test for a pallet file:
If the cursor in the pallet file is on a pallet entry, the control runs
the tool usage test for the entire pallet.
If the cursor in the pallet file is on a program entry, the control
runs the tool usage test only for the selected NC program.
Using a tool usage test
Before starting a program in the Program Run, Full Sequence/
Single Block operating modes, you can check whether the tools
being used in the selected NC program are available and have
sufficient remaining tool life. The control then compares the actual
tool-life values from the tool table with the nominal values from the
tool usage file.
Press the TOOL USAGE soft key
Press the TOOL USAGE TEST soft key
The control opens the Tool usage test pop-up
window indicating the result of the usage test.
Press the OK soft key
The control closes the pop-up window.
Alternative: Press the ENT key
You can query the tool usage test with the FN 18 ID975 NR1
function.