HEIDENHAIN TNC 620 User Manual page 361

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

MOD functions | Setting up touch probes
Soft key
Function
Select the SE transceiver
Select the strength of the infrared signal
You only need to change the signal strength if
there is interference.
Select the strength of the radio signal
You only need to change the signal strength if
there is interference.
The Switching on/off connection setting is preset based on the
type of touch probe. Under Deflection, you can select how the touch
probe is to transmit the signal when probing.
Deflection
Meaning
IR
Infrared probe signal
Radio
Radio probe signal
Radio + IR
The control selects the probe signal
You can activate the touch probe per soft key in the "Properties" tab
(e.g., in order to test the radio connection)
If you activate the touch probe's radio connection
manually per soft key, then the signal remains unchanged
even after a tool change. You must deactivate the radio
connection manually again.
Current radio touch probe data
The control displays the following information in the "Current radio
touch probe data" area:
Display
Meaning
NO.
Number in the touch probe table
Model
Type of touch probe
Status
Touch probe active or inactive
Signal
Display of the signal strength in the bar graphic
strength
The control shows the currently best-known
connection as a complete bar
Deflection
Stylus deflected or not deflected
Collision
Collision or no collision recognized
Battery status
Display of the battery quality
If the charge is less than the displayed bar, then
the control outputs a warning.